Astm d93 flash point tests by penskymartens closed cup. Rapid flash closedcup tester 115v k16502 koehler k16502 for international destinations rapid flash closedcup tester 230v k16591 list price. Buy koehler k16200 penskymartens closedcup flash tester, 115 vac60 hz and more from our comprehensive selection of koehler manual flash point testers covid19 update. A good lubricant should have flash and fire point above its working temperature. Recc and flash, no flash ip523, iso 3679, ip492, en iso 1523 recc ip 524, en iso 3680, ip 491, en iso 1516, recc, flash, no flash continuously closed cup flashpoint. Penskymartens flash point tester procedure adam flink.
Flash point testers clarkson laboratory and supply inc. Rapid flash tester 1 flash point testers instrument designed to test and determine a samples flash point, or the temperature at which the samples vapors ignite. Numerous test methods are built in to accommodate various samples. Pensky martens, tag, abel and cleveland open cup coc. Procedure of using the penskymartens flash point tester at btc process technology lab. Basics of penskymartens closedcup flash point testing. The automatic abel closedcup tester measures the flash point, the lowest temperature at which the vapors of a sample ignite.
Therefore, vapor concentration can be determined by temperature. Note 1 flash point determination as above 250c can be performed, however, the precisions have not been determined above this temperature. Firefighters should wear selfcontained breathing apparatus. To support you, coleparmer is open for business and shipping product daily. A wide variety of pensky martens flash point apparatus diagram options are available to you. Astm d93 19 standard test methods for flash point by. Product description the koehler k7 automatic penskymartens closed cup flash point analyzer is for flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing.
Equipped with electronic temperature controller, variable area flowmeters, level and overtemp alarm. The penskymartens closedcup flash point test is a test for the determination of the flash point of flammable liquids. Slow speed gear motor rotates stirrer of penskymartens tester at 115rpm for procedure a and at. This apparatus is made as per ip 34, astmd93 and is 1448 part i 1270 p.
For flash point by penskymartens closed cup tester pdf download. We are having different types of flash point apparatus used for different oils. The automatic penskymartens closedcup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. To determine the flash and fire point temperatures of the given sample of oil kerosene using pensky martens closed cup apparatus. Qualtech products industry professional automatic flash point tester is a precision penskymartens closedcup flash point test instrument to determine the flash point of volatile samples. The flash point of a volatile material is the lowest temperature at which it can vaporise to form an ignitable mixture in air. Flash and fire point pensky martens closed cup apparatus conduct an experiment to determine the flash point and fire point of a given oil using pensky martens closed cup apparatus aim. Improper use andor negligence may result in serious personal injury or.
For flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing. Koehler instrument flash point cup for penskymartens closed tester flash point test cup spectrophotometers, refractometers and benchtop instruments. It is not appropriate for flash point determinations to be carried out on potentially unstable, decomposable, or explosive materials, unless it has been previously established that heating the specified quantity of such materials in contact with the metallic components of the flash point apparatus, within the temperature range required for the. All information contained in this material safety data sheet is furnished free of charge and is intended for. Basically, this is the temperature in which a liquid can burst into flames.
For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Makes penskymartens, tag, and abel flash point testing. Semiautomatic pensky marten flash point apparatus flash point is lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test. Flash point testing was developed in the late 1800s and has been refined and automated over the decades to produce the automatic penskymartens closed cup testers which are on the market today. At that moment, the flash point apparatus can determine and measure the vapor pressure change in which this occurs, also known as the lowest limit of flammability. Manual flash point analyzers pensky martens, tag, abel and cleveland open cup coc hfp 38x series topquality laboratory analyzers for closed and open cup flash point determinations electric stirrer automatic application of test flame optional cooling device advantages designed to provide years of accurate and reliable. Flash detection the hfp is equipped with a thermal detection system to eliminate interference from water or silicone containing samples. This manual provides operating instructions for the k16273 penskymartens closed cup flash point testers, and should be used in conjunction with applicable standard test methods. Standard test methods for flash point by penskymartens closed cup tester details three procedures under a shared method for determining flash point. Penskymartens closed cup automatic flash point tester.
Closedcup testing according to penskymartens is a reliable and safe way of determining the flash point of liquid and semisolid petroleum products. Factors affecting the flash point and fire point of. To avoid personal injury andor equipment damage, strictly observe these important safety precautions at all times. Koehler k16200 penskymartens closedcup flash tester, 115. Abel closed cup flash point tester 220240v 5060hz koehler k17490 automatic abel flash point tester 115v 60hz. Procedurea for homogeneous petroleum liquids such as distillate fuels, procedureb for residual fuel oils and some other nonhomogeneous liquids, procedurec for biodiesel, spe mode for samples with unknown. Independent or networked operation the hfp flash point analyzer may be used as a standalone instrument or connected to a second herzog flash point. Included is a user friendly manual machine interface, electric standard or gas optional ignition and thermal detection.
Differently from many equipment on the market having electronics subject to overheating and quick ageing because placed on the bath cover, ours has a. It tells the maximum temperature up to which a lubricant can be used. With an integrated fire extinguisher, the penskymartens flash point tester pma 5 highly improves user safety. Generally, the fire point is 510 0 c higher than the flash point for any lubricant. Measuring a flash point requires an ignition source. Flash point of cutback asphalt with tag opencup apparatus. Koehler instrument flash point cup for penskymartens. Pma 5 comes completely ready for testing with automatic test routines, userdefinable. Flash point testing equipments pensky marten flash point.
Ordering information hfp 339 pensky martens flash point analyzer is a compact and selfcontained instrument for precise flash point determination. In order to ensure safe operation of the apm7 flash point tester, this manual makes use of warnings and caution messages such as those below. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. The flash point is the lowest temperature at which a liquid sample vaporizes to form an ignitable mixture with air. For flash point determinations of liquids with a viscosity of below 5. Fire detection in extended range around test cup and flash detection outside the cup. Pensky marten flash point apparatus pmfpa ask for price.
Test methods for flash point by penskymartens closed cup tester pdf 1 pg, 75 k contact us to ask a question, provide feedback, or report a problem. Koehler k7 penskymartens closedcup flash point tester. Manufacturer of flash point apparatus abel flash point instrument, pensky martin closed cup flash point instrument, coc cleveland open cup flash point tester offered by acute instruments private limited, navi mumbai, maharashtra. Exporter of flash point testing equipments pensky marten flash point tester, abel closed cup flash point apparatus, cleveland open cup flash point tester offered by wadegati labequip private limited, mumbai, maharashtra. Cleveland open cup flash point test coc rapid equilibrium methods recc. Standard test methods for flash point by penskymartens. It is standardized as astm d93, en iso 2719 and ip 34 the united states environmental protection agency epa.
268 67 544 586 1148 224 1427 914 402 1511 883 915 705 472 760 1100 631 65 947 1118 1458 973 137 737 322 650 492 546 402 386 192 893 8 312 6 1276 540